Ods 2 inertsil.
Inertsil ODS-2 Packed Guard Columns.
Ods 2 inertsil. In addition, you may see ODS followed by a number designation:. Inertsil ODS-3V. 0, and have known to provide good stability even at pH approaching 11. 2) Phenol 3) Salicylic acid. Buy Inertsil ODS-2 C18 HPLC Column 5 µm 150 x 4. 25 cm × 4. Shop Online. Inertsil ODS-2 is one of the most popular phase and continues to be used widely and reliably for long established methods in pharmaceutical and environmental labs. = 1. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. A un pH superior a 8, los geles de sílice comienzan a disolverse; a un pH ácido por debajo de 2,0, ciertas fases ligadas (particularmente CN) se hidrolizan y puede ocurrir una pérdida Inertsil® ODS-2 HPLC Column 5 μm particle size, L × I. Acetonitrile 100 % Ion- exchange Inertsil CX, AX etc. Inertsil ODS-EP. Reversed phase Columns (C18 Column) Inertsil ODS-3 Analytical Columns. 6 30 5020-87315 5020-87321 5020-87327 50 5020-87316 5020-87322 5020-87328 75 5020-87317 5020-87323 5020-87329 100 5020-87318 5020-87324 5020-87330 2 Inertsil ODS-SP XTerra MS C18 01020 Time (min) 1 2 020 Time (min) Luna ODS(2) 1 2 Gemini C18 020 Time (min) 1 2 Atlantis dC18 020 Time (min) 0 204 060 80 mVolt 1 2 Oxine-copper shows tailing. Assy. In addition, the introduction of higher surface area silica provide high preparative loading capacity without sacrificing peak shape which is illustrated in Figure 2. 0 and 10. 6 mm at Sigma-Aldrich GL Sciences Official Store. Learn More. These phases represent a major advance in the analysis of basic, acidic and amphoteric compounds. 6 x 250mm Otras columnas Inertsil®, como ODS-2, ODS-3 y ODS -4 proporciona una vida útil óptima cuando se utiliza con eluyentes dentro del rango de pH de 2,0 a < 8. Inertsil ODS-4 delivers the same extreme inertness to any type of compounds just like InertSustain C18 along with unprecedented stability under 100 % aqueous mobile phases for qualitative and quantitative analysis. ODS-2 phase detail Reversed phase C18 column Jan 24, 2024 · Inertsil ODS-2. 0 to < 8. SMT Elite-C18. Vast database of chromatographic applications available to assist in method development. Zorbax Eclipse XDB-C18 020 Time (min) 1 2 shows tailing. The Inertsil ODS-3 series represents a major advance in performance over the original Inertsil ODS-2 Series. 6 mm 8 mm 10 mm 16 mm 20 mm 25 mm 30 mm 40 mm 50 mm 70 mm 100 mm Weight 1 g 3 g 10 g 1000 g : Inertsil ODS-2 . 5. Inertsil Ph. Inertsil WP300 C18 Part Number Short Description Phase Type Phase USP Particle Size ID Length Pore Size Type Price Qty; 5020-01128 : Inertsil ODS-2 Column, 5um, 4. High-Density bonding of C18 phase delivers alternative selectivity to conventional C18 columns. These phases utilize a 99. Pursuit ® XRs C18 ACE C18 YMC-Pack ODS-AM GL Sciences Official Store. YMC-Pack ODS-AM Symmetry ® C18 Kromasil ® C18 LiChrosorb ® RP-18 NUCLEODUR ® C18 NUCLEOSIL ® C18 Inertsil ® ODS-2 C18 Acclaim™ C18. 6 mm; Synonyms: Inertsil® ODS-2 15 cm X 4. 6 mm (5020-01128). Inertsil ODS-SP. Spherisorb CN OBD: Inertsil ODS-2: C18: SunFire C18: ACQUITY UPLC HSS T3: SunFire C18. Base Material: 2 Series High Purity Silica Gel: Particle Size: 5 µm: Surface Area: 320 m 2 /g: Pore Size: 150 Inertsil ODS-HL Inertsil® ODS-HL Analytical Columns * End-fittings are 1/16” Waters-compatible. As the carbon load of Inertsil ODS-SP is relatively low, it is compatible with 100 % aqueous eluents and offer faster equilibration of column for Inertsil ODS-HL; Inertsil ODS-4; Inertsil ODS-3; Inertsil ODS-4V (バリデーションカラム) Inertsil ODS-3V (バリデーションカラム) Inertsil ODS-SP; Inertsil ODS-P; Inertsil ODS-EP; Inertsil WP300 C18; Inertsil ODS-80A [ 販売終了 ] Inertsil ODS-2; Inertsil ODS InterClone ODS(2) can be used for methods that require Inertsil ODS(2) InertClone ODS(2) InertClone ODS(2) HPLC columns are a guaranteed alternative to Intertsil Inertsil ODS-2 columns have a pore size of 150 Å offering symmetric peaks for bases, acids with low pressure. Inertsil ODS-2. SunFire C18 OBD: Inertsil ODS-3: C18: SunFire C18: ACQUITY UPLC HSS T3: SunFire C18. Inertsil ODS columns are general purpose, reversed phase C18 columns available in 5 μm and 10 μm particle sizes. Filter Options. 6 mm at Sigma-Aldrich Inertsil ODS-2. 0 mm (5020-01122). 0 to 7. Inertsil ODS-2 columns have a pore size of 150 Å offering symmetric peaks for bases, acids with low pressure. Use this well-tested, dependable L1. Guaranteed Replacement to Inertsil HPLC Columns. Inertsil ODS-EP Analytical Columns Inertsil ODS-EP contains a polar functional group embedded between the silica surface and the C18 group. 0 mm (5020-01127). Exceptional physical and chemical durability provides long column life. Inertsil ODS-2 Specifications Form Column Guard Bulk Particle Size 5 µm 10 µm Length 13 mm 20 mm 30 mm 33 mm 40 mm 50 mm 60 mm 75 mm 100 mm 125 mm 150 mm 200 mm 250 mm 300 mm Length 5 mm 10 mm 20 mm Inner Diameter 2 mm 3 mm 4 mm 4. Methanol 100% The original 2-Series Inertsil phases, including Silica, C4, C8, ODS-2 and Phenyl, created the high purity silica revolution in the late 1980s. Intersil ODS-2 is manufactured by GL Science. 3 1 2. Inertsil ODS-3 is still GL Sciences’ most popular phase and continues to be used world widely and reliably for long established methods in pharmaceutical, and contract research labs. Functional Group. The difference between the two phases is just the length of the hydrocarbon ligands. Buy Inertsil ODS-2 C18 HPLC Column 5 µm 150 x 3. (mm) 2. 999% pure silica get which is extremely durable and free from dents and cracks which can cause premature column failure. Starting from the purest reagents, the silica is manufactured, bonded with C-18 and endcapped. 6 mm; Synonyms: PK4 Inertsil® ODS-2 Guard Columns; find -506087 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich Inertsil ODS-2 Cartridge Guard Column E. XSelect HSS C18 XP. At pH above 8, silica gels begin to dissolve; at acidic pH below 2. If the mobile phase contain buffers or additives, equilibrate the column and system Reversed Phase Columns (C18 Column) Inertsil ODS-3V (Specifically Qualified HPLC Columns for GLP/GMP Compliance Validation) Inertsil ODS-3V offers all of the outstanding chromatographic benefits of Inertsil ODS-3 with the added benefit of a more thoroughly documented, validated QC procedure consistent with the demands of GLP/GMP compliance. 0 4. Hypersil stationary phases are recognized as an industry standard in HPLC. When Inertsil ODS-2 was introduced in 1987s, this HPLC transformed the entire industry. XSelect HSS C18 Inertsil ODS-2 Preparative Columns. HILIC-phase InertSustain Amide Inertsil HILIC, Amide etc. The Spherisorb ODS2 Columns operate best in pH range 2 to 8. 0mm replacement guard cartridges 5020-08510-ODS2 This is only a partial listing. Inertsil 3 CN: Cyano: ACQUITY UPLC CSH Fluoro-Phenyl. Virtually free of trace metal contaminants which can cause peak tailing. Comparison of inertness to strong acidic compounds between Inertsil ODS-4 and commercially ODS columns 1) Brilliant Blue FCF. Inertsil ODS-P. 6 mm at Sigma-Aldrich 1. 0 Inertsil ODS-SP is super base deactivated and optimally bonded to retain hydrophilic compounds without excessive retention of hydrophobic compounds achieving better separations faster than before. Please visit www. XSelect CSH Fluoro-Phenyl. Inertsil ODS-2 was the first HPLC phase created using ultra high purity silica, which produced superior base deactivation. Inertsil C8 columns have a pore size of 150 Å and it is recommended for rapid analysis of highly hydrophobic compounds. 6 mm at Sigma-Aldrich 3 μm ODS-3: high efficiency alternative to the 5 μm ODS-3 columns; Columns stable from pH 2 to 9 . It was the first ODS bonded phase introduced from GL Sciences back in 1986. Reversed Phase Columns (C8, C4 Columns) Inertsil C8 Analytical Columns. In general, elution time of Inertsil ODS-4 is shorter than InertSustain C18 and ODS-3. Other Inertsil columns, such as ODS-2, ODS-3, and ODS-4 provide optimum lifetime when used with eluents within the pH range of 2. Inertsil ODS-2 was the fi rst HPLC phase created using ultra high purity silica, which produced superior base deactivation. 1 cm × 4. Buy Inertsil ODS-2 C18 HPLC Column 5 µm 250 x 4. 1 3. Inertsil ODS-2 Packed Guard Columns. GL Sciences Official Store. Meet preparative and 0 2 4 6 8 10 12 Time (min) Inertsil ODS-4. D. " Reversed Phase Columns (C18 Column) Inertsil ODS-4 Analytical Columns. n-Hexane : Ethanol -Phase InertSustain C18, AQ-C18, Phenyl, PFP, Cyano etc. HP Series Particle Size:3 μm Max. As shown in Figure 1, Inertsil ODS-3 has a relatively strong retentivity compared to commercially available ODS columns. 6 mm HPLC Column at Sigma-Aldrich Inertsil® ODS-2 HPLC Column 5 μm particle size, L × I. Inertsil ODS-2 Columns. The embedded polar group makes the C18 phase stable in 100 % aqueous eluents without "phase collapse. ・Inertsil ODS-4, ODS-3, ODS-SP, ODS-2 Reversed-Phase Methanol/Water Columns 5. GL Sciences offers a polymerically bonded ODS-P phase which provide high steric selectivity for separation of planar and non-planar compounds. 020 Time (min) 0 204 0 608 0 mVolt Synergi MAX-RP 1 2 Oxine-copper shows tailing. Symmetry C18 Inertsil ODS-2 Guard Columns Cartridge Guard Column E Cartridge guard column E designed with a special holder and cartridge, universal self-adjusting connections, reusable by changing cartridges. Inertsil ODS-4V. Higher pHs leads to dissolve the silica gel and lower pHs cause to hydrolyze away some of the bonded phase. Inertsil ODS-HL employs a highly inert packing material which provides pure hydrophobic interaction between analytes without generating any secondary interaction delivering sharp peaks. Inertsil® ODS-2 HPLC Column 5 μm particle size, L × I. The same base silica gel and bonding technology that is used for Inertsil ODS-3 is also employed for Inertsil C8-3. Order ; Inertsil® ODS-2 HPLC Column 5 μm particle size, L × I. 16 ˜ Eluent pH : Inertsil columns provide optimum lifetime when used with eluents within the pH range of 2. Luna ® C8 Symmetry ® C8 Acclaim™ C8 Kromasil ® C8 LiChrosorb ® RP-8 NUCLEODUR ® C8 NUCLEOSIL ® C8 Inertsil ® C8-2 Sunfire ® C8. For instance, you can expect a shortened column lifetime with the use of phosphate buffer at pH 8 in combination with raised temperature. ACQUITY UPLC HSS CN: XSelect HSS CN. Part of the most popular and trusted HPLC column series for more than 25 years. Water : Acetonitrile InertSustain NH2 with 100% CH 3 CN etc. Inertsil Ph-3. nertsil ODS-P columns are also ideal for the HPLC analysis of 16 PAH compounds, listed as target pollutants by the US EPA. 6 mm; find Supelco-50108U MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich Guaranteed Replacement to Inertsil HPLC Columns Prodigy™ columns have been developed as alternatives to the Inertsil® 3μ ODS-3, 5μ C8, C8-3, Phenyl-3, ODS-2, ODS-3 and ODS-3V packings. The original 2-Series Inertsil phases, including ODS-2, C8, Ph, C4, and SIL-150A°, created the high purity silica revolution in the late 1980s. 5020-0024 Revised date September 24, 2019 4/4 page SPECIFIC TARGET ORGAN TOXICITY - repeated exposure - : No adverse effects were seen in lung function and chest radiography of workers exposed to dust of this substance for an average of 8. Inertsil ODS-3 Series phases are based on a purer, higher surface area silica which is specially manufactured to provide maximum bonded phase coverage. inertsil. 1210P010W040 Inertsil ODS-2 5 micron 2 x 10 x 4. We recommend InertSustain C18 or Inertsil ODS-4 columns for all new method development. 10 μm particle size columns are also available to meet the requirement of various pharmacopeia methods. Reversed Phase Columns (C18 Column) Inertsil ODS-P Analytical Columns. SDS No. com for a complete listing or inquire by phone at the number shown below. Base Material: 2 Series High Purity Silica Gel: Particle Size: 5 µm: Surface Area: 320 m 2 /g: Pore Size: 150 Inertsil® ODS-2 HPLC Column 5 μm particle size, L × I. 15 cm × 4. Intersil ODS-2 meets rigid quality control tests and is well suited for a wide range of applications, including basic drugs, amines and other challenging samples. 2(1991)). Outstanding peak shape for acids and bases. Thermo Scientific™ Hypersil™ ODS-2 C18 HPLC Columns are an alternative to older column brands commonly referenced in validated methods. 6 mm (5020-01124). Inertsil ODS-2 was the first HPLC phase created using ultra high purity silica, which produced superior base deactivation. GL Sciences Inertsil ODS-2 columns have a pore size of 150Å offering symmetric peaks for bases, acids with low pressure. 5 years (ACGIH(7th,2001), ECETOC JACC(2006), SIDS(2006), DFGOT vol. Inertsil ODS-4, ODS-3, C8-3, Ph-3 etc. Filled with stationary phase compositions or chemical compounds, the prepacked options reduce the preparing time required. It is excellent at inertness. Inertsil ODS. 6 mm; Synonyms: PK4 Inertsil® ODS-2 Guard Columns; find -506087 MSDS, related peer-reviewed papers, technical documents, similar products & more at Sigma-Aldrich Feb 23, 2016 · Sometimes, you may see a Partisil HPLC column referred to as “ODS. 6 mm HPLC Column at Sigma-Aldrich Inertsil ODS-HL; Inertsil ODS-4; Inertsil ODS-3; Inertsil ODS-4V (バリデーションカラム) Inertsil ODS-3V (バリデーションカラム) Inertsil ODS-SP; Inertsil ODS-P; Inertsil ODS-EP; Inertsil WP300 C18; Inertsil ODS-80A [ 販売終了 ] Inertsil ODS-2; Inertsil ODS Inertsil® ODS-2 HPLC Column 5 μm particle size, L × I. AOSl l d i 1994 b ill i h il d ll h ld Inertsil ODS-3 Inertsil ODS-SP Inertsil ODS-EP An ODS column released in 1994, but still is heavily used all over the world because of its strong hydrophobic property and excellent Inertsil® ODS-2 HPLC Column 5 μm particle size, L × I. SMT O C8. XSelect HSS CN XP. ODS-80A was originally introduced to provide a higher surface area alternative to ODS-2, but with the same inertness and base-deactivated properties. Operating Pressure: 50 MPa (500 Bar) Length / I . Applications: Basic drugs GL Sciences Inertsil ODS-2 columns have a pore size of 150Å offering symmetric peaks for bases, acids with low pressure. 高純度シリカゲル母体 ODS 充填剤として、世界に Inertsil ブランドを定着させたロングヒット ODS カラムです。 モノタロウサイトでは、今後Internet Explorer(IE)11のサポートを終了いたします。 Inertsil ODS-3 は、市販 ODS カラムの中でも非常に保持力が強く、またイオン性化合物の吸着も少ないため、非常に使いやすい ODS カラムです(図 1)。 そのバランスの良さが評価され、発売当初から世界中で幅広い支持を受けています。 Inertsil SIL -100A ,CN 3 NH2 Diol etc. Base Material :2 Aeries High Purity Silica Gel: Particle Size :5 µm: Surface Area :320 m 2 /g: Pore Size Chromatography columns separate molecules within mixtures during gas or liquid chromatography. Column lifetimes will vary and also depend on the operating temperature, and the type and concentration of buffer used. Inertsil ODS 2. ” This means the column has an Octadecyl silane (C18) stationary phase. plt evteu kmezpv zjfdrq pwnxxe yuo uwi tcasbq mzxl rnmpnr